Auxiliary boiler burner lockout

Boilers · Alfa Laval Aalborg

MarineMedium difficulty

Symptoms

Failure to ignite, flame failure alarm, smoke at start-up.

Probable causes

  • Dirty flame sensor (photocell)
  • Clogged fuel nozzle
  • Low fuel pressure
  • Ignition electrodes out of adjustment

Solution

Clean the photocell and the nozzle, check fuel pressure and temperature, adjust the electrodes and test the flame programmer sequence.

The information on this page is general guidance. It does not replace the manufacturer’s manual or the work of a qualified technician: before any intervention, always check procedures, tightening torques and safety requirements in the official documentation of the machine.

Field experiences

No experience has been published for this fault yet. If you have dealt with it, tell us how you solved it: photos and drawings help whoever faces the same situation.

Need a technical assessment?

Send photographs, nameplates, serial numbers, drawings or part numbers for an initial review.